Overview



The PowerWalker VFI 1000-3000 ICR IoT series is the next generation of UPS, offering an intuitive App for remote monitoring via cloud. The UPS is quickly setup and easy to maintain, and it provides the ability to review the workflow and troubleshoot instantly regardless of time and place. This cloud based monitoring increases the availability and quality of traditional monitoring, while at the same time allowing room for cost reduction, scalability, and trend analysis.

This UPS series utilizes double conversion (Online) technology and features unity power factor, ensuring the availability of your mission critical equipment and providing clean output power to your sensitive loads. Multiple optional accessories such as external battery packs, communication cards and a WLAN adapter enhance the functionality of the UPS.




At-a-glance



  • Built-in ethernet port offers Modbus TCP/ IP

  • EBM Auto-Detection for easy setup of External Baterry Packs

  • Hot-Swappable Batteries!

  • IoT Solution with the PW-WinPower App

  • Optimized Battery Management (OBM) – for longer Battery Life

  • Output Power Factor 1.0




Reasons to buy


  • Built-in ethernet port offers Modbus TCP/ IP
  • EBM Auto-Detection for easy setup of External Baterry Packs
  • Hot-Swappable Batteries!
  • IoT Solution with the PW-WinPower App
  • Optimized Battery Management (OBM) – for longer Battery Life
  • Output Power Factor 1.0

Specification


Technical Description: PowerWalker VFI 1000 ICR IoT UK uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 1000 W 8 AC outlet(s)

Battery
Hot-swap battery:
Yes
Battery recharge time(90%):
3 h
Charging current:
1.5 A
Typical backup time at half load:The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
11.8 min
Typical backup time at full load:The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
4.2 min
Number of batteries supported:The number of batteries that can be used with the product.
3
Battery voltage:The voltage (V) of the battery.
12 V
Battery capacity:The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h).
7 Ah

Design
International Protection (IP) code:The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes".
IP20
Display type:Type of display (screen) e.g. LCD.
LCD
Built-in fan:
Yes
Rack capacity:The spase that device fill in rack.
2U
Product colour:
Black
Form factor:The shape or design of the product.
Rackmount/Tower

Features
Noise level:The amplitude level of the undesired background noise, usually measured in decibels (db).
45 dB
Input current Total Harmonic Distortion (THD):
5%
Output voltage Total Harmonic Distortion (THD):
1%
Emergency Power Off (EPO):
Yes
ECO mode:
Yes
Crest factor:
3:1
Output power factor:
1
Power factor:
1
Efficiency:
89%
Number of output phases:
1
Number of input phases:
1
Output voltage regulation:
1%
Output frequency regulation:
0.2 Hz
Output operation voltage (max):The maximum output voltage produced by the device.
240 V
Output operation voltage (min):The minumum voltage produced by the device during operation.
200 V
Input frequency:The frequency (Hz) which is required to power the product.
40 - 70 Hz
Input operation voltage (max):The maximum input voltage supported by the device.
300 V
Input operation voltage (min):The minumum voltage needed by the device during operation.
160 V
Waveform:
Pure sine
Output power:The power that the device can produce.
1000 W
Output power capacity:The maximum power that the device can produce.
1 kVA
UPS topology:
Double-conversion (Online)

Operational conditions
Operating relative humidity (H-H):
0 - 95%
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C

Packaging data
Quick installation guide:
Yes
Manual:
Yes
Cables included:
Input power cable, USB cable

Ports & interfaces
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
1
RS-232 ports:The number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
1
USB port:Universal Serial Bus (USB) is an industry standard developed in the mid-1990s that defines the cables, connectors and communications protocols used in a bus for connection, communication, and power supply between computers and electronic devices. USB was designed to standardize the connection of computer peripherals (including keyboards, pointing devices, digital cameras, printers, portable media players, disk drives and network adapters) to personal computers, both to communicate and to supply electric power. It has become commonplace on other devices, such as smartphones, PDAs and video game consoles. USB has effectively replaced a variety of earlier interfaces, such as serial and parallel ports, as well as separate power chargers for portable devices.
Yes
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
8 AC outlet(s)
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C14 coupler
AC outlet types:The type of outlet for AC electricity.
C13 coupler

Weight & dimensions
Package weight:Weight of the packaged product.
17.3 kg
Package height:The distance from the top to the bottom of the packaging.
240 mm
Package depth:The distance from the front to the back of the packaging.
587 mm
Package width:The distance from one side of the packaging to the other.
498 mm
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
14.3 kg
Height:The measurement of the product from head to foot or from base to top.
86 mm
Depth:The distance from the front to the back of something.
445 mm
Width:The measurement or extent of something from side to side.
438 mm


Product details


10122208 PowerWalker 4260074983142

PowerWalker VFI 1000 ICR IoT UK uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 1000 W 8 AC outlet(s)

£391.99 and In stock

SKU10122208

PowerWalker VFI 1000 ICR IoT UK uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 1000 W 8 AC outlet(s)

Quick Code: Q1281598 MPN: 10122208
£391.99

In Stock

Key Features

  • IoT Solution with the PW-WinPower App
  • Output Power Factor 1.0
  • Hot-Swappable Batteries!
  • Built-in ethernet port offers Modbus TCP/ IP