Overview



Infosec E3 Performance 800 RT. UPS topology: Double-conversion (Online), Output power capacity: 0.8 kVA, Output power: 720 W. AC outlets quantity: 8 AC outlet(s). Battery recharge time: 4 h. Form factor: Rackmount/Tower, Product colour: Black, Rack capacity: 2U. Compliance certificates: RoHS, Certification: EN62040-2: 2006+AC: 2006 (EN 61000-3-2: 2014, EN61000-4-2:2009, EN61000-4-3:2006+A2: 2010,...




Specification


Technical Description: Infosec E3 Performance 800 RT uninterruptible power supply (UPS) Double-conversion (Online) 0.8 kVA 720 W 8 AC outlet(s)

Battery
Battery recharge time:Approximate time required to recharge the battery from completely empty to completely full
4 h

Certificates
Certification:
EN62040-2: 2006+AC: 2006 (EN 61000-3-2: 2014, EN61000-4-2:2009, EN61000-4-3:2006+A2: 2010, EN61000-4-4: 2012, EN61000-4-5: 2006, EN61000-4-6: 2014, EN61000-4-8: 2010, EN61000 -2-2: 2002) EN62040-1:2008+A1:2013
Compliance certificates:
RoHS

Certification
Certification:
EN62040-2: 2006+AC: 2006 (EN 61000-3-2: 2014, EN61000-4-2:2009, EN61000-4-3:2006+A2: 2010, EN61000-4-4: 2012, EN61000-4-5: 2006, EN61000-4-6: 2014, EN61000-4-8: 2010, EN61000 -2-2: 2002) EN62040-1:2008+A1:2013
Compliance certificates:
RoHS

Design
LED indicators:
Yes
Display type:Type of display (screen) e.g. LCD.
LCD
Rack capacity:The spase that device fill in rack.
2U
Product colour:
Black
Form factor:The shape or design of the product.
Rackmount/Tower

Features
Audible alarm modes:
Alarm when on battery, Fault, Low battery alarm, Overload alarm
Audible alarm(s):Alarms that make a sound when they are activated (set off).
Yes
Power protection features:Features that protect the device against power problems e.g. overload.
Over voltage, Overdischarge, Overload
Surge protection features:
Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone
Surge protection:
Yes
Noise level:The amplitude level of the undesired background noise, usually measured in decibels (db).
45 dB
Output voltage Total Harmonic Distortion (THD):
2%
Emergency Power Off (EPO):
Yes
Crest factor:
3:1
Power factor:
0.9
Efficiency:
97%
Number of output phases:
1
Number of input phases:
1
Output frequency:
50/60 Hz
Output operation voltage (max):The maximum output voltage produced by the device.
240 V
Output operation voltage (min):The minumum voltage produced by the device during operation.
110 V
Input frequency:The frequency (Hz) which is required to power the product.
50/60 Hz
Input operation voltage (max):The maximum input voltage supported by the device.
290 V
Input operation voltage (min):The minumum voltage needed by the device during operation.
81 V
Waveform:
Sine
Output power:The power that the device can produce.
720 W
Output power capacity:The maximum power that the device can produce.
0.8 kVA
UPS topology:
Double-conversion (Online)

Operational conditions
Operating relative humidity (H-H):
0 - 90%
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C

Packaging data
Bundled software:Software distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
InfoPower

Ports & interfaces
Emergency Power Off (EPO) connector:
Yes
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
2
Modem (RJ-11) ports:
2
RS-232 ports:The number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
1
Serial interface:
Yes
USB 2.0 ports quantity:Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
1
USB port:Universal Serial Bus (USB) is an industry standard developed in the mid-1990s that defines the cables, connectors and communications protocols used in a bus for connection, communication, and power supply between computers and electronic devices. USB was designed to standardize the connection of computer peripherals (including keyboards, pointing devices, digital cameras, printers, portable media players, disk drives and network adapters) to personal computers, both to communicate and to supply electric power. It has become commonplace on other devices, such as smartphones, PDAs and video game consoles. USB has effectively replaced a variety of earlier interfaces, such as serial and parallel ports, as well as separate power chargers for portable devices.
Yes
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
8 AC outlet(s)

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
12.9 kg
Height:The measurement of the product from head to foot or from base to top.
88 mm
Depth:The distance from the front to the back of something.
425 mm
Width:The measurement or extent of something from side to side.
438 mm


Product details


67023 Infosec

Infosec E3 Performance 800 RT uninterruptible power supply (UPS) Double-conversion (Online) 0.8 kVA 720 W 8 AC outlet(s)

£409.99 and In stock

SKU67023

Infosec E3 Performance 800 RT uninterruptible power supply (UPS) Double-conversion (Online) 0.8 kVA 720 W 8 AC outlet(s)

Quick Code: Q1897688 MPN: 67023
£409.99

In Stock