Overview



APC Basic Rack PDU , Input: 400V 3PH , Input Connections: IEC 309 16A 3P+N+PE , Cord Length: 3 feet ( 0.91 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19.

- Low Cost Power Distribution.
- Vertical mounting capability.
- Toolless mounting capability.
- Multi-branch power input.




Specification


Technical Description: APC Rack PDU, Basic, Zero U, 11 kW, 230V, (36) C13 & (6) C19 power distribution unit (PDU) 42 AC outlet(s) 0U Black

Certificates
Certification:
C-tick,CCC,CE,GOST,MIC,Queensland Australia,VD

Certification
Certification:
C-tick,CCC,CE,GOST,MIC,Queensland Australia,VD

Design
Product colour:
Black
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Basic

Features
Cable length:How long the cable is.
0.91 m

General
Type:Characteristics of the device.
Power Distribution Units (PDUs)

Operational conditions
Operating relative humidity (H-H):
5 - 95%
Storage relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
-5 - 45 °C

Ports & interfaces
Output connections:
(36) IEC 320 C13 (6) IEC 320 C19
Input connection type:The type of connection /port for the input(s) into this device e.g. USB.
IEC 309 16A 3P+N+PE
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
11000 W
Maximum total current draw per phase:
16 A
Maximum input current per phase:
16 A
Load capacity:
11040 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
230 V
AC input frequency:
47/63 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
400 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
5.45 kg
Height:The measurement of the product from head to foot or from base to top.
1619 mm
Depth:The distance from the front to the back of something.
44 mm
Width:The measurement or extent of something from side to side.
56 mm


Product details


AP7557 APC 0731304254102

APC Rack PDU, Basic, Zero U, 11 kW, 230V, (36) C13 & (6) C19 power distribution unit (PDU) 42 AC outlet(s) 0U Black