Overview



When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 1U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG5308 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 8 port outlets that can power up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG5308 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 35.04 kw equivalent of power consumption of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.

Real-time Alerts via LCD Display
Once connected to an AC power source, the Home screen displays basic PDU readings, including A (Aggregate Current), V (Voltage), W (Power), and kWh (Power Consumption).

The LCD screen lights up red when a Critical, Alert (triggered when a PDU value exceeds a predefined threshold), or Warning (when a value approaches the alert threshold) event is logged.

Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors (i.e. EA1640, sold separately) for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.

Communicate through RS-232 Protocol
For quick and flexible operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands.

Networkable via WiFi
The PG8308 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.

Dual LAN Ports for Scalable Network Setup
The PG8308 is equipped with dual LAN ports (Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.

DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.

Applications
The PG series intelligent PDUs are perfectly suited to server rack installation requiring energy-efficient power distribution to high-density IT equipment in server rooms or data centers.




At-a-glance



  • Dual 1G Ethernet ports support cascading up to 64 PDUs

  • Environment sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 ATEN EA1640 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats (sold separately)

  • Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking

  • With an ARM Cortex-A8 processor, these PDUs provide advanced control options through USB, COM, environmental sensors, and dual Gigabit LAN ports




Reasons to buy


  • Dual 1G Ethernet ports support cascading up to 64 PDUs
  • Environment sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 ATEN EA1640 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats (sold separately)
  • Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking
  • With an ARM Cortex-A8 processor, these PDUs provide advanced control options through USB, COM, environmental sensors, and dual Gigabit LAN ports

Specification


Technical Description: ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software

Certificates
Certification:
CE, UKCA

Certification
Certification:
CE, UKCA

Design
Display:The description of display that can includes display type, resolution, size etc.
LCD
Product colour:
Black
Rack capacity:The spase that device fill in rack.
1U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered

Features
Cable length:How long the cable is.
3 m
LED indicators:
Yes
Reset button:
Yes

Logistics data
Country of origin:Country where the device is made.
Taiwan

Management features
Monitoring:
Current, Voltage

Operational conditions
Operating relative humidity (H-H):
0 - 80%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-20 - 60 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 60 °C

Ports & interfaces
USB ports quantity:
1
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
2
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC 60309
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
8 AC outlet(s)

Power
Load capacity:
7680 VA
Output voltage:
100 - 240 V
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
32 A
AC input frequency:
50-60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
100 - 240 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
3.99 kg
Height:The measurement of the product from head to foot or from base to top.
44 mm
Depth:The distance from the front to the back of something.
432.4 mm
Width:The measurement or extent of something from side to side.
210 mm


Product details


PG5308G ATEN 4710469349560

ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software

£526.99 and In stock

SKUPG5308G

ATEN 32A 8-Outlet 1U Metered PDU + Free Eco PDU Manager Software

Quick Code: Q2711613 MPN: PG5308G
£526.99

Quantity: